Logo

bugs

data structures and software dependability

computer science department

brandenburg university of technology cottbus - senftenberg

Summary: Read arcs have no effect on TF0 and FP0
Created: 2011-05-12 20:43
Status: Closed
Category: Bug
From: wegener?
Assigned:
Priority: 4
Program: Charlie
Version:
Description:
When there is a read arc connected to a transition that does not have a "normal" post-place it is considered as a boundary transition.

When there is a read arc connected from a place that does not have an pre-transition then it is considered as a boundary transition.

A read arc should be considered as an arc that directs into both directions and thus neither of the examples above should be considered as boundaries.


Comments

Fix is in PlaceTransitionNet line 510.


<< 00024 | CharlieBugList | 00026 >>

… the end …